Monday, October 18, 2010

Drying Effects

More on the contact angles will be posted when I compile a couple of more samples, but for now here are some images of the effects of drying the samples with CO2 gas versus air when wet with water. The samples were prepared by vapor deposition, similar to the procedure used in prior blog postings. The pictures are: Amine surface [N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane] after drying with CO2 (top left), air dry (bottom left), formamidine functionalized with CO2 drying (top right) and formamidine functionalized with air drying (bottom right). The magnification of these pictures is 5x ( I apologize for no scale bars).







Thursday, October 7, 2010

More contact angle measurements

Continuing from the last post, here are the contact angles of the converted amine surfaces to amidine surfaces:

With CO2 in water treatment for 5 minutes:
75.4 +/- 2.9 (Advancing)
32.0 +/- 3.4 (Receding)

With N2 in water treatment for 5 minutes:
80.6 +/- 2.2 (Advancing)
29.6 +/- 6.4 (Receding)

Tuesday, October 5, 2010

Amine Functionalized Slides Contact Angle Measurements

The initial contact angles of 3-aminopropyl-dimethyl ethoxysilane:

Slide 1: 73.8 +/- 1.9 (Advancing)
23.4 +/- 4.6 (Receding)

Slide 2: 73.6 +/- 2.8 (Advancing)
25.8+/- 2.9 (Receding)

This compares with 68.4 and 45.2 (advancing and receding respectively, Smith and Chen, Langmuir 2008, 24, 12405-12409)

Only variations to their procedure were UVO treatment opposed to Piranha etching and the post-cure step was done under vacuum rather than ambient atmosphere.

Two more samples prepared at the same time, that were reacted to form the formamidine analog, will be posted their contact angles, dry, with water/N2 and with water/CO2, will be posted tomorrow.

Monday, September 20, 2010

Amidne Glass Surface Roughness

Images shown below are AFM images of formamidine functionalized glass. The top two are two separate examples of when samples were submerged and N2 gas was bubbled in. The bottom two are examples of when CO2 is bubbled in. All of the areas are 3x3 um and the scan rate is 1 Hz. The height ranges from 0-25 nm.






Thursday, July 22, 2010

Acetamide Amidine Functional Glass Plots

Left: A graph of 3 different locations on one Acetamide derived amidine functionalized glass

Right: A graph of CO2 and non-CO2 exposed Acetamide derived amidine functionalized glass

  • Both were tested with a relatively fresh PDMS probe (1o:1) (week old)
  • Non-CO2 samples were exposed to Nitrogen gas in 250 ml of water in a closed container
  • CO2 samples were exposed to "Bone Dry" CO2 gas in 250 ml of water in a closed container, with the water being changed after every sample to maintain a relatively constant initial pH



Thursday, July 1, 2010

G vs V for formamidine glass with and without CO2 exposure

Here are critical release energy (G) values vs. velocity for formamidine functionalized surfaces. There are three runs for each sample (with and without CO2). The location was not changed, so this is three adhesion tests on the same spot. Any comments are appreciated! And thanks again to Al and Chelsea for the help on the data analysis.



Thursday, June 3, 2010

Results soon...