Monday, October 18, 2010

Drying Effects

More on the contact angles will be posted when I compile a couple of more samples, but for now here are some images of the effects of drying the samples with CO2 gas versus air when wet with water. The samples were prepared by vapor deposition, similar to the procedure used in prior blog postings. The pictures are: Amine surface [N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane] after drying with CO2 (top left), air dry (bottom left), formamidine functionalized with CO2 drying (top right) and formamidine functionalized with air drying (bottom right). The magnification of these pictures is 5x ( I apologize for no scale bars).







Thursday, October 7, 2010

More contact angle measurements

Continuing from the last post, here are the contact angles of the converted amine surfaces to amidine surfaces:

With CO2 in water treatment for 5 minutes:
75.4 +/- 2.9 (Advancing)
32.0 +/- 3.4 (Receding)

With N2 in water treatment for 5 minutes:
80.6 +/- 2.2 (Advancing)
29.6 +/- 6.4 (Receding)

Tuesday, October 5, 2010

Amine Functionalized Slides Contact Angle Measurements

The initial contact angles of 3-aminopropyl-dimethyl ethoxysilane:

Slide 1: 73.8 +/- 1.9 (Advancing)
23.4 +/- 4.6 (Receding)

Slide 2: 73.6 +/- 2.8 (Advancing)
25.8+/- 2.9 (Receding)

This compares with 68.4 and 45.2 (advancing and receding respectively, Smith and Chen, Langmuir 2008, 24, 12405-12409)

Only variations to their procedure were UVO treatment opposed to Piranha etching and the post-cure step was done under vacuum rather than ambient atmosphere.

Two more samples prepared at the same time, that were reacted to form the formamidine analog, will be posted their contact angles, dry, with water/N2 and with water/CO2, will be posted tomorrow.