Compression Testing of Amine Layers

In this sequence of microscope images (2.5 x magnification), a glass probe was compressed against glass slide samples that were prepared on 10-12-2010 with N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane as the layer. The top image is that of the probe coming into contact with a large droplet and compressing down to 1 g of force on a glass slide that has had CO2 added to it. The second droplet is another image of the same slide, however this time the compression test was done on an area that did not have a large droplet. The third image is that of the same silane treatment, but a sample that has not had any CO2 added at all. The scale bar for all three images is 500 microns and all of these images are at the point of maximum force applied.




2 comments:

Al said...

Looks like you have a fluid in the non-CO2 treated slide. Is this what you're trying to show? If so, what do the P vs. d curves look like---and make sure when you think about this to consider the different volumes of the droplets that you are contacting.

Sam said...

I will post those soon, what I was trying to convey was the difference of the contact radius in the samples, with and without CO2. The third image (with CO2, but not on top of a droplet) was to show that, you still get a larger contact radius at the same force, even when contact is not on top of a large droplet.

As to the comment about the droplets on the non-CO2, I noticed that as well, but I think that has more to do that there is inevitably some CO2 even if you do not add it, these samples are from 10-12-2010, almost two months. XPS data I think points to some CO2 present even if you do not add CO2 to the sample.

Post a Comment

Note: Only a member of this blog may post a comment.