Wednesday, May 9, 2012

Contact of the Lines



In these pictures, we first show a picture of a glass slide.  Next, a PDMS patterned CD pattern was placed on and watched as it established contact with the surface.  Finally, when the PDMS has more force applied, the contact becomes even more intimate to the surface.  In the second picture, the darker side is in contact with the surface and the surface continues to bring itself into contact with the glass.  In the first contact phase, the diffraction patterns are still apparent, although they are diminished slightly.  As the structures, move into the darkest region, the diffraction pattern is no longer visible, indicating the structure has collapsed.

In all three pictures, the lines are relatively running up and down.  When the contact is established during the collapse of the structures, the contact propagates parallel to the lines.

Adhesion of Carbon Fiber-F-15 Samples on Smooth Glass

In these samples, I kept the dimensions of the samples equivalent from the previously mentioned samples, however this time I put resin on the entire tendon, rather than just the patterned area.  This was done in order to keep the stress distribution along the fabric more constant that previous tests.  In this case, the orthogonal sample provided the highest adhesion, 50% more than an unpatterned substrate.  The parallel case had an adhesion increase of about 15%.


Thursday, April 26, 2012

Patterned Adhesion-2

Here are more plots of patterned adhesion that were performed with a Nylon backing and F-15 polyurethane.  F-15 is a very nice polyurethane for replicating features.  Once again, the parallel orientation of the features produces the highest improvement on the adhesion, regardless of the pitch size.  In order to eliminate variables, the samples produced were ~ 4 cm^2 in the patterned region (ca. 2 x 2 cm), with the exception of the orthogonal CD pattern, which was smaller in the width, due to defects in the sample.  However, in that case, the area remained comparable to the other samples, by keeping the length longer.



Tuesday, April 24, 2012

Patterned adhesion photos

In this photo, there are the 5 samples that were tested in the last post.  From left to right: Non-patterned, CD-Orthogonal, CD-Parallel, DVD-Orthogonal, DVD-Parallel.  In all of the samples, the distance between the top of the clamping and the bottom of the patterned feature is 4 cm, this is held constant in all of the samples, as well as the other previously tested samples.  All of the samples were produced from a 4 cm wide and 10 cm long piece of 1k 2-D carbon fiber.  The patterned area typically ranges from 7-10 cm^2, depending on the type of mold and if defects were present on the edges of the sample that were removed.  The size discrepancy of the molds, particularly between orthogonal and parallel samples arises from limitations of the CD or DVD disk size in the radial direction.  The edges are trimmed off in order to eliminate edge effects that arise when resin wicks over the mold.    The bottom of the samples are not this messy or frayed when they are tested, this is a result of pulling the fabric off of a layer of scotch tape that is used to hold the sample down in the clamp.


 

Monday, April 23, 2012

Patterned Adhesion with Composites

In these experiments, 5 composites were made with 2-D (orthotropic) carbon fibers (1k) and F-15 polyurethane resin.  One sample was left unpatterned as a control sample to compare how features effect adhesion.  Two samples were created with a CD pattern, one with the lines running parallel to the straining direction and one orthogonal to the straining direction.  This was also repeated with a DVD pattern to compare two different size pitches.  The adhesion results are posted below with the adhesion in N/cm2 and the second graph is the normalized adhesion compared to the unpatterned surface.  All of these samples were tested for their adhesion on three different surfaces: Smooth glass, Frosted Glass and Painted Steel to evaluate the effect of different surface roughness on the adhesion.


The patterns with the CD features appear to do better than smooth samples in all three surfaces.  DVD patterns did better in the smooth adhesion, but not in the roughness.  One possibility is that since these features are smaller than the roughness, it may have a hard time fitting in and thus compromising the ability to adhere.  In the CD the patterns are closer to the size of the roughness, and thus may be able to accommodate roughness better in the trenches.  More tests will follow on other substrates, it took a few attempts to get a fairly consistent replicating method.

Thursday, April 21, 2011

Caviation with Artificial Appendages

In the sequence below, you can see an appendage from the Mantis Shrimp molded from Norland Optical 60, creates cavitation in water as it moves. The first image on the left is the appendage at the initial rest position, the center one is a position where cavitation is beginning to form and then the final image is a larger cavity formed. One interesting thing to note is that the appendage slows down considerably after cavitation. This cavitation effect is also observed in samples made from 2-P and both materials survive the testing process without breaking.

We (Suzanne and I) have about 24 new samples to test with 5 different sizes made from both materials (2-P only in some cases), and 3 samples of each to gather statistics within each sample and to observe possible roughness effects from the mold.

Monday, March 28, 2011

Dry CO2 exposure in Glovebag and Adhesion


Here is a force vs. displacement curve for two glass surfaces treated with a 21 hour vapor exposure of N-(2-ethylamino)-3-aminopropyl trimethoxysilane. One of the surfaces was left untreated, the second one was left in a glove bag for 2 hours under a dry N2 gas purge. Following the purge, the sample was exposed to a 90 second exposure to "Bone Dry" Grade CO2 in the same glove bag. The sample exposed to CO2 showed very little change in contact angle measurements. Here is the force vs. displacement curve for the two samples and little differences were exhibited in the adhesion.